MI0810A301 Chip‑Type Digital Pyroelectric Infrared Sensor
Category:
- Product Description
-
Product Overview
The surface-mount digital pyroelectric sensor MI0810A301 employs a dedicated human‑body infrared processing integrated circuit as its built-in signal‑processing chip. The thermal motion signals detected by the pyroelectric sensing element are fed into the digital chip’s high‑impedance input, where they are converted into 16‑bit digital signals and subjected to digital bandpass filtering. The filtered 16‑bit data is then output serially via the DOCI interface.
Product Features
* Low power consumption, energy-efficient and environmentally friendly, with extended battery life.
* Chip‑on‑board package, suitable for SMD reflow soldering.
* Integrated bandpass filter with strong anti-interference performance, effectively suppressing RF interference from mobile phones, Wi‑Fi, and other sources;
* Wide operating voltage range: 2.5V - 5.0V.
* Digital signal output.
* The peripheral circuit is simple.
Product Applications
* Intelligent security protection, including infrared motion detection
* IoT infrared motion detection
* Automatic lighting control for stairwell lights, indoor lights, corridors, etc.
* Solar-powered automatic sensor light
* The smart home appliance sector, including refrigerators, air conditioners, televisions, and more
* Placeholder detection
Electrical Performance Parameters
1. Maximum Rated Parameters
Any electrical stress exceeding the parameters listed in the table below may result in permanent device damage. Operating under these maximum-rated conditions may compromise the device’s reliability.
Parameter Symbol Minimum value Maximum value Unit Note Power supply voltage V DD -0.3 5.5 V Pin Limit Into -100 100 mA One pin at a time Storage temperature Test -40 85 °C 2. Operating parameters (ambient temperature 25°C)
Parameter Symbol Minimum value Typical value Maximum value Unit Note Operating voltage V DD 2.5 3.3 5 V Operating current I 10 25 microampere Operating temperature T -20 70 °C DOCI Mode Data Read Timing Sequence DOCI interrupt acquisition t s 40 60 150 microseconds Data clock low-level duration T L 0.5 1 20 microseconds T L + T H + t bit <25 μs Data clock high-level duration T H 0.5 1 20 microseconds Data bit setup time t bit 5 10 50 microseconds Data cycle T REP 16 ms Filters and Oscillators Low-pass filter cutoff frequency F L 7 Hz High-pass filter cutoff frequency F H 0.44 Hz On-chip oscillator frequency Fosc 32 kilohertz Internal block diagram
3. Function Description
a) Bandpass filter
A second-order low-pass filter and a third-order high-pass filter are cascaded to form a band-pass filter, with corresponding passband frequency ranges of:
0.44 Hz to 7 Hz.
b) DOCI Serial Data Read Timing
DOCI serial data reading is divided into two types: reading based on the interrupt signal of the MI0810A301, and forced reading by defining a timing sequence via the microcontroller.
Reading Based on the Interrupt Signal of MI0810A301
MI0810A301 generates an active interrupt signal every 16 ms, meaning DOCI is pulled high by MI0810A301 and remains high for two system clock cycles. After waiting 100 ns, the microcontroller asserts a rising edge on the DOCI line and then begins reading the data. The first bit read is the most significant bit. This process is repeated until all 16 bits have been read. Once the last bit has been read, the microcontroller must force DOCI low and release it immediately. The DOCI timing diagram is shown in Figure 2, where the solid blue line indicates the microcontroller’s drive and the dashed line indicates MI0810A301’s drive.
Figure 1 DOCI Timing Based on Interrupt Signal Readout
① When the DOCI interface is neither in read mode nor equal to 1, the serial interface completes data updating and generates an interrupt‑valid signal, causing MI0810A301 to go high, thereby asserting DOCI.
②MI0810A301 Pull the DOCI line high and maintain it for at least two system clock cycles.
③ The microcontroller pulls the DOCI line low for at least 200 ns.
④ The microcontroller generates a rising edge on the DOCI line, and the high level on the DOCI line is maintained for at least 200 ns.
⑤ DOCI line switching status, outputting the most significant bit (MSB) of the data.
⑥ The microcontroller samples the data’s most significant bit (MSB).
⑦ Repeat steps ③, ④, ⑤, and ⑥; the microcontroller samples the second most significant bit of the data.
⑧ Repeat steps ③, ④, ⑤, and ⑥; the microcontroller samples the least significant bit (LSB) of the data.
⑨ After data reading is complete, the microcontroller forces DOCI to a low level and immediately releases the DOCI line.
⑩ Repeat step ① to begin a new read cycle.Force a read by defining the timing sequence via the microcontroller.
In this readout mode, as shown in Figure 2, the microcontroller ignores interrupt signals, forces the DOCI line high for at least two system clock cycles, and then begins reading data just as it would in interrupt‑mode readout. To ensure that the output data latch is updated, the microcontroller must either release the DOCI line (triggering automatic data update, similar to the interrupt cycle) or force the DOCI line low for at least 64 system clock cycles (forcing a data update).
Figure 2 DOCI timing during forced read defined by the microcontroller
① The microcontroller ignores the interrupt enable signal from MI0810A301 and directly pulls DOCI high.
② The microcontroller pulls the DOCI line high and maintains it for at least two system clock cycles.
③ The microcontroller pulls the DOCI line low for at least 200 ns.
④ The microcontroller generates a rising edge on the DOCI line, and the high level on the DOCI line is maintained for at least 200 ns.
⑤ DOCI line switching status, outputting the most significant bit (MSB) of the data.
⑥ The microcontroller samples the data’s most significant bit (MSB).
⑦ Repeat steps ③, ④, ⑤, and ⑥; the microcontroller samples the second most significant bit of the data.
⑧ Repeat steps ③, ④, ⑤, and ⑥; the microcontroller samples the least significant bit (LSB) of the data.
⑨ After data reading is complete, the microcontroller forces DOCI to a low level and maintains it for at least 64 system clock cycles to finalize the serial‑port data update. Alternatively, as shown in Figure 2, the microcontroller pulls DOCI low and immediately releases the DOCI line, enabling automatic data updating via interrupt mode.
⑩ Repeat step ① to begin a new read cycle.Regardless of the reading method employed, the data-reading process can be terminated at any time.
As shown in Figure 3, item ⑦, during the read operation, if the DOCI interface remains at a low level for more than one system clock cycle, the data read process is terminated, and the output data latch is updated.
Figure 3: The read operation terminates because DOCI remains at a low level.
As shown in Figure 4, during the read operation, the DOCI interface is forced high, causing the read process to terminate; however, the output data latch remains unchanged.
Figure 4: The read process ends due to DOCI being forcibly pulled high.
The DOCI interface outputs the values of the high-pass filter. The valid data output by DOCI, as shown in Figure 5, comprises 23 bits: a preamble of 2 bits (10), 16 data bits, a postamble of 1 bit (0), and a four-bit optional parity code (0xx0).
Figure 5 Data on the DOCI Interface
4. Data Format
Note: *Overflow flag—“0” indicates normal operation, while “1” indicates that the sensor output has exceeded the internal chip’s conversion range, resulting in data overflow.
*Check the parity bit: when bits B16 through B1 contain an odd number of “1”s, the parity bit outputs “1”; when they contain an even number of “1”s, it outputs “0”.
The last four bits are optional read bits, but the least significant bit of the read data must be “0”; therefore, the number of read bits must be 19, 20, or 23.
*To convert data B16 through B1 into a signed binary code, the data must be processed as follows: when B16 is “0,” the data remains unchanged; when B16 is “1,” the bits from B15 to B1 are inverted, and 1 is added to B1. The resulting data has B16 as the sign bit—“0” denotes positive and “1” denotes negative—while B15 through B1 represent the binary value, corresponding sequentially to the most significant bit through the least significant bit.5. External Dimensions
Reference circuit
Product Reference Reflow Soldering Temperature Profile
Welding precautions:
1. Do not exceed the maximum temperature shown on the temperature curve in the figure above; otherwise, sensor performance may degrade.
2. Do not repeatedly perform reflow soldering or subject the component to repeated heating and disassembly, as this may degrade sensor performance or render it inoperable.
3. After the sensor is mounted, allow it to stand at room temperature before use; we recommend waiting one hour.
4. Sensor failure caused by temperatures or durations exceeding those shown in the diagram is not covered under warranty.
Precautions
MI0810A301 is a digital pyroelectric infrared sensor that detects changes in infrared radiation. It may fail to detect heat sources other than the human body, or temperature variations and movements in the absence of a heat source. Please note the following: be sure to verify its performance and reliability under actual operating conditions.
1. When detecting heat sources other than the human body, the sensor is prone to false alarms.
1.1 When a small animal enters the detection range.
1.2 When the sensor is directly exposed to far-infrared radiation from sunlight, car headlights, incandescent lamps, and the like.
1.3 When the temperature in the test area undergoes significant fluctuations due to warm air, cold air, or water vapor from humidifiers originating from the cold‑room equipment.
2. The phenomenon of the heat source not being detected occurs.
2.1 Between the sensor and the object being detected, there may be materials such as glass or acrylic that are opaque to mid- and far-infrared radiation.
2.2 Within the detection range, when the heat source is nearly stationary or moving at extremely high speed.
3. In the case of an expanded detection area
When the temperature difference between the ambient environment and the human body is significant (approximately 20°C or more), the detection area may sometimes appear to expand even outside the specified detection range.
4. Notes on Other Uses
4.1 During testing, the Fresnel lens and the finished housing must be installed first (the sensor’s housing must not be left exposed); otherwise, the sensing performance may be compromised, and wind can easily cause false triggers.
4.2 When stains adhere to the window, detection performance may be affected; please take note.
4.3 The lens supplied with the probe is made of a fragile material (polyethylene). Applying excessive load or impact to the lens may cause deformation and damage, leading to trigger instability or performance degradation; therefore, such conditions should be avoided.
4.4 Applying static electricity exceeding ±200 V may cause damage. During operation, take care to avoid direct contact with terminals and other components using your hands.
4.5 Frequent or excessive vibration may cause the sensor’s internal sensing element to fracture; handle with care during use.